This standard provides requirements for protective gloves that are worn in an environment producing ionising radiation or in an environment containing radioactive substances.
A glove protecting against radioactive contamination must be waterproof according to EN374-2.
A glove that protects against ionising radiation must, in addition to being waterproof according to EN374-2, contain a certain amount of heavy metal such as lead.
Connection element or equipment component. A connector can be karabiner or a snap hook.
Class A: Anchorage connector, automatic lock used as the component and designed to be connected directly to a specific type of anchorage.
Class B: Primary connector with automatic lock used as the component.
Class M: Multi-purpose connector, primary or quick opening, used as a component, which can be loaded along its major axis or minor axis.
Class Q: Quick opening connector used in long-term or permanent applications, screw lock. When completely screwed this part is a supporting part of the
connector.
Class T: Manufactured end connector, automatic lock, designed as part of a subsystem for attachment so that the load is carried in a predetermined direction.
Element of a fall arrester system to which a personal protective equipment can be fastened.
Type A - NON PPE : Anchor device with one or more stationary anchor points with the need of a structural anchor.
Type B: Anchor device with one or more stationary anchor points without the need of a structural anchor.
Type C - NON PPE : Anchor device employing a flexible anchor line with maximum deviation of 15°.
Type D - NON PPE : Anchor device employing a rigid anchor line with maximum deviation of 15°.
Type E: Anchor device for use on surfaces with a maximum slope of 5°.
Equipment consisting of a mobile fall arrester with self-locking, integral with its rigid anchorage line (rail, cable…). An energy reducer can be built-in on the equipment.