Standards and directives

We operate in a regulated global market in many countries. Thus, we must manage requirements that may vary greatly between countries or regions.
The common goal of our product managers and services is to offer reliable, sustainable, high-performance products in compliance with the regulations and/or standards of each territory where they are used.
#
#

Standards and certifications

All you need to know about PPE standards

Filter
Standards

EN354 LANYARDS

Connection elements or equipment component. A lanyard can be in rope made of synthetic fibres, in metallic rope, in strap or in chain.
CAUTION: A lanyard without energy absorber must not be used as a fall arrest equipment.

Categorisation

Taking into account the level of risk covered, the Regulation defines the PPE categories and determines the various manufacturer’s obligations:
PPE category 1: Protection against minor risks.
PPE category 2: All PPE that are not category 1 or 3.
PPE category 3: Protection against disability or fatality

CSA Z94.3

This safety eyewear standard covers eye and face protectors for applications in Canada.

THE REGULATION (European Union)

Its objective is to develop test methods and requirements in the form of standards defining the technical specifications of products. Some of them, mostly requirements standards, are harmonised with EU Regulation 2016/425. Compliance with these harmonised standards gives an assurance of compliance with the requirements of EU Regulation 2016/425

ANSI (US American National Standards Institute) Z87.1

Specifications and minimum general requirements, test methods, selection, use and maintenance of eye and face protection.

GS-ET 29

Requirements, performances, test methods relating to face shields providing protection against electric arcing.

ANSI (US American National Standards Institute) S3.19 - 1974

This standard specifi es the test method for determining the level of noise attenuation (NRR Noise Reduction Rating) of the hearing protection, as recommended by the EPA (U.S. Environmental Protection Agency).

EN ISO 374-5 AGAINST THE DANGERS OF MICRO-ORGANISMS

EN ISO 374-5 specifies the requirements and test methods for protective gloves intended to protect the user against microorganisms (mold and bacteria, potentially viruses).

Penetration of molds and bacteria (tested according to EN374-2): Test by which the water and airtightness of a glove is checked.

Penetration of viruses (tested according to method B of ISO 16604): Process that determines the resistance to penetration by blood-borne pathogens.

- Test method using Phi-X174 bacteriophage.

The glove, depending on its type, will bear the following pictogram:

 

 

Examples of application:

The field of use is decisive because, depending on the case, the glove may have to combine several properties in order to meet the necessary protection requirements. It is therefore very important to refer to the recommended areas of use and the results of the laboratory tests found in the instructions for use. However, it is recommended to check that the gloves are suitable for the intended purpose by carrying out tests beforehand, because the conditions at the workplace may differ from those of the standard test, depending on the temperature, abrasion and degradation.