Güvenlik standartları
Ürün ve hizmet yöneticilerimizin ortak hedefi, kullanıldıkları her bölgenin yönetmeliklerine ve/veya standartlarına uygun, güvenilir, dayanıklı, yüksek performanslı ürünler sunmaktır.
Connection elements or equipment component. A lanyard can be in rope made of synthetic fibres, in metallic rope, in strap or in chain.
CAUTION: A lanyard without energy absorber must not be used as a fall arrest equipment.
Taking into account the level of risk covered, the Regulation defines the PPE categories and determines the various manufacturer’s obligations:
• PPE category 1: Protection against minor risks.
• PPE category 2: All PPE that are not category 1 or 3.
• PPE category 3: Protection against disability or fatality
This safety eyewear standard covers eye and face protectors for applications in Canada.
Its objective is to develop test methods and requirements in the form of standards defining the technical specifications of products. Some of them, mostly requirements standards, are harmonised with EU Regulation 2016/425. Compliance with these harmonised standards gives an assurance of compliance with the requirements of EU Regulation 2016/425
Specifications and minimum general requirements, test methods, selection, use and maintenance of eye and face protection.
Requirements, performances, test methods relating to face shields providing protection against electric arcing.
This standard specifi es the test method for determining the level of noise attenuation (NRR Noise Reduction Rating) of the hearing protection, as recommended by the EPA (U.S. Environmental Protection Agency).
Type 1: The impact force transmitted to the cap must not exceed 4,450 N when a 3.6 kg (8 lb) impact is dropped at a speed of 5.5 m/s (metres per second).
Penetration: A 1 kg penetrator must not come into contact with the false head at a speed of 7.0 m/s.
Flammability: the helmet must not burn with the emission of a fl ame for more than 5 seconds after the fl ame has been withdrawn
Electrical resistance: proof test at 20,000 volts for class E or 10,000 volts for class G. Class C off ers no protection against electrical hazards.
Type 2: In addition to the requirements of type 1, type 2 head protection must also satisfy:
Energy attenuation: the acceleration must not exceed 150 g in the event of a fall onto the cap and sideways using a 5 kg dummy head at 3.5 m/s.
Lateral penetration: At the front, rear and sides, a 1 kg penetrator must not come into contact with the headform at a speed of 5.0 m/s.
ANSI/ISEA Z89.1 4 options: low temperature (LT), high temperature (HT), reverse wear position and high visibility.
EN ISO 374-5 specifies the requirements and test methods for protective gloves intended to protect the user against microorganisms (mold and bacteria, potentially viruses).
Penetration of molds and bacteria (tested according to EN374-2): Test by which the water and airtightness of a glove is checked.
Penetration of viruses (tested according to method B of ISO 16604): Process that determines the resistance to penetration by blood-borne pathogens.
- Test method using Phi-X174 bacteriophage.
The glove, depending on its type, will bear the following pictogram:
Examples of application:
The field of use is decisive because, depending on the case, the glove may have to combine several properties in order to meet the necessary protection requirements. It is therefore very important to refer to the recommended areas of use and the results of the laboratory tests found in the instructions for use. However, it is recommended to check that the gloves are suitable for the intended purpose by carrying out tests beforehand, because the conditions at the workplace may differ from those of the standard test, depending on the temperature, abrasion and degradation.
Standard ISO 18889 specifies the performance requirements of protective gloves for pesticide operators and re-entry workers.
G1 gloves are suitable when the potential risk is relatively low. These gloves are not suitable for use with concentrated pesticide formulations and/or for scenarios where mechanical risks exist. G1 gloves are typically single use gloves.
G2 gloves are suitable when the potential risk is higher. These gloves are suitable for use with diluted as well as concentrated pesticides. G2 gloves also meet the minimum mechanical resistance requirements and are therefore suitable for activities that require gloves with minimum mechanical strength.
GR gloves provide protection only to the palm-side of the hand for a re-entry worker who is in contact with dry and partially dry pesticide residues that remain on the plant surface after pesticide application.
Standard EN ISO 10819 specifies performance requirements for vibration attenuation through gloves. The vibration-reducing material must also satisfy thickness and consistency requirements. It should be noted that these gloves can reduce but not eliminate health risks associated with handtransmitted vibration exposure.
Vibration transmissibility in one-third-octave frequency bands from 25 to 200Hz must be equal to or less than 0.90. The one calculated in one-third-octave frequency bands from 200 to 1250 Hz must be equal to or less than 0.60.
Specification of level numbers and requirements relating to the transmittance of filters for protection against solar radiation, industrial use.